CHAPTER 760 Nursing and Boarding Care Homes — Chapter Overview
CHAPTER 760 Nursing and Boarding Care Homes
| Document type | chapter |
|---|---|
| Identifier | 760 |
| Citation | Chapter 760 |
| Ordinances detected | S, 116-84, 45-64 |
| Original source | American Legal Publishing |
| Content hash | c35cfe27718dfebc9501cdfa2c0652cf2320ff526b4b2f8b5e8bc5a897dcd4b2 |
Skip to main content
Search
Sitemap
Login
Select Language
Resources
Skip to code content (skip section selection)
2025-04 (current)
Sheffield Lake Overview
Codified Ordinances of Sheffield Lake, OH
CODIFIED ORDINANCES OF THE CITY OF SHEFFIELD LAKE, OHIO
CERTIFICATION
ROSTER OF OFFICIALS
ADOPTING ORDINANCE NO. 116-84
COMPARATIVE SECTION TABLE
TABLES OF SPECIAL ORDINANCES OF SHEFFIELD LAKE
CHARTER
PART ONE - ADMINISTRATIVE CODE
PART THREE - TRAFFIC CODE
PART FIVE - GENERAL OFFENSES CODE
PART SEVEN - BUSINESS REGULATION CODE
CHAPTER 706 Abortions
CHAPTER 709 Adult Foster Care
CHAPTER 712 Amusements
CHAPTER 718 Fire Protection/Fighting Equipment
CHAPTER 724 Frozen Desserts
CHAPTER 730 Garage Sales
CHAPTER 748 Mechanical Amusement Devices
CHAPTER 750 Computerized Internet Sweepstakes Cafes
CHAPTER 760 Nursing and Boarding Care Homes
760.01 DEFINITIONS.
760.02 SUBMISSION OF PLANS.
760.03 CONSTRUCTION.
760.04 USE OF THIRD FLOOR.
760.05 USE OF ATTICS, BASEMENTS AND CELLARS.
760.06 OTHER OCCUPANCY.
760.07 LOCATION.
760.08 EGRESS FACILITIES REQUIRED.
760.09 EGRESS PASSAGEWAYS.
760.10 EXIT SIGNS.
760.11 ILLUMINATION OF EXIT PASSAGES.
760.12 STORAGE OF GASES.
760.13 FLAMMABLE LIQUIDS, STORAGE AND USE.
760.14 FIRE EXTINGUISHING EQUIPMENT REQUIRED.
760.15 FIRE HOSE AND STANDPIPES.
760.16 SPRINKLERS REQUIRED.
760.17 HAZARDOUS OCCUPANCIES.
760.18 LOCATION NEAR FLAMMABLE LIQUID STORAGE TANKS.
760.19 ATTENDANTS.
760.20 EVACUATION PLAN.
760.21 SMOKING. (REPEALED)
760.22 HOUSEKEEPING.
760.23 ELECTRICAL WIRING.
760.24 FIRE PROTECTION.
760.99 PENALTY.
CHAPTER 761 Private Investigators and Security Guards
CHAPTER 772 Peddlers, Solicitors and Canvassers
CHAPTER 780 Snow Plowing
CHAPTER 784 Taxicabs
CHAPTER 790 Fair Housing
PART NINE - STREETS, UTILITIES AND PUBLIC SERVICES CODE
PART ELEVEN - PLANNING AND ZONING CODE
PART THIRTEEN - BUILDING CODE
PART FIFTEEN - FIRE PREVENTION CODE
OH
Sheffield Lake
Codified Ordinances of Sheffield Lake, OH
CHAPTER 760 Nursing and Boarding Care Homes
CHAPTER 760 Nursing and Boarding Care Homes
CHAPTER 760
Nursing and Boarding Care Homes
760.01 Definitions.
760.02 Submission of plans.
760.03 Construction.
760.04 Use of third floor.
760.05 Use of attics, basements and cellars.
760.06 Other occupancy.
760.07 Location.
760.08 Egress facilities required.
760.09 Egress passageways.
760.10 Exit signs.
760.11 Illumination of exit passages.
760.12 Storage of gases.
760.13 Flammable liquids, storage and use.
760.14 Fire extinguishing equipment required.
760.15 Fire hose and standpipes.
760.16 Sprinklers required.
760.17 Hazardous occupancies.
760.18 Location near flammable liquid storage tanks.
760.19 Attendants.
760.20 Evacuation plan.
760.21 Smoking. (Repealed)
760.22 Housekeeping.
760.23 Electrical wiring.
760.24 Fire protection.
760.99 Penalty.
CROSS REFERENCES
State Fire Marshal - see Ohio R.C. Ch. 3737
National Electrical Code - see BLDG. Ch. 1307
Dangerous buildings - see BLDG. Ch. 1351
760.01 DEFINITIONS.
As used in this chapter:
(a) "Ambulatory" means a person who, without the aid of another, is physically and mentally capable of walking a normal path to safety, including the ascent and descent of stairs.
(b) "Approved" means acceptable to the State Fire Marshal.
(1) "Approved standards" means any standard or code prepared and adopted by any nationally recognized association.
(2) "Approved equipment and material" means any equipment or material tested and listed by a nationally recognized testing laboratory.
(c) "Approved organized fire department" means any municipal corporation, town or village or political subdivision that has adequate fire fighting equipment and manpower subject to the control and approval of the State Fire Marshal.
(d) "Area of refuge" means a ground area, reasonably accessible from a building of sufficient size and in safe condition for refuge by all building occupants at a safe
distance from such building. When used in relation to areas within buildings this term means an area beyond a fire wall or smoke barrier of sufficient size to offer refuge to all occupants on the same floor of the building.
(e) "Attic" means the space between the ceiling beams of the top habitable story and the roof rafters.
(f) "Automatic sprinkler system" means an arrangement of piping ad sprinklers designed to operate automatically by the heat of fire and to discharge water upon the fire.
(g) "Basement" means that portion of the building partly underground, but having less than half its clear height below the average grade of the adjoining ground.
(h) "Bed patient" means a person who is not ambulatory.
(i) "Boarding care home" means a home licensed to provide care for aged or infirm persons requiring or receiving personal care or custodial care.
(j) "Cellar" means that portion of the building partly underground, having half or more than half of its clear height below the average grade of the adjoining ground.
(k) "Combustible" means that which is not within the category of "noncombustible", as defined herein.
(l) "Exit" means the exit doorway or doorways, or such doorways together with connecting hallways or stairways, either interior or exterior, or fire escapes, designed to provide means by which individuals may proceed safely from a room or space to a street or to an open space which provides safe access to a street.
(m) "Fire wall" means a wall of brick or reinforced concrete having adequate fire resistance and structural stability under fire conditions to accomplish the purpose of completely subdividing a building or of completely separating adjoining buildings to resist the spread of fire. A fire wall shall extend continuously through all stories from the foundation to or above the roof.
(n) "Incombustible" means the same as "noncombustible", as defined herein.
(o) "Means of egress" has the same meaning as "exit", as defined herein.
(p) "New homes" include new construction, additions to existing licensed homes, existing buildings converted to nursing or boarding care homes and transfers of ownership for which a new license is required.
(q) "Noncombustible", when used in relation to any material thing, means that which will not readily ignite and burn when subject to fire.
(r) "Nursing home" means a home licensed to provide care for aged or infirm persons requiring or receiving nursing care.
(s) "Patient" means any individual cared for in a nursing home, even though such person does not require nursing care.
(t) "Resident" means any individual cared for in a boarding care home.
(u) "Smoke barrier" means a partition with a fire-resistance rating of not less than one- half hour, equipped with a door and jamb of the same rating and hung so as to be reasonably smoke and gastight when closed. The door shall be not less than forty- four inches wide and shall not be fastened in an open position by a device which will require more than one movement of normal strength to swing such door to a closed position. Such barrier shall be located to provide ample area of refuge on each side of such partition or barrier for all occupants served by the barrier. The barrier may have wired-glass panels, each not to exceed six square feet. The wire- glass shall be standard clear wire-glass.
(v) "Sprinklered" means to be completely protected by an approved system of automatic sprinklers installed and maintained in accordance with approved standards.
(w) "Story" means that part of a building between a floor and the floor or roof next above and applies to the basement and other floor areas below. The first floor shall be that story which is of such height above grade that it does not come within the definition of a basement or shall be that story located immediately above a basement.
(Ord. 45-64. Passed 10-15-64.)
Disclaimer: This Code of Ordinances and/or any other documents that appear on this site may not reflect the most current legislation adopted by the Municipality. American Legal Publishing provides these documents for informational purposes only. These documents should not be relied upon as the definitive authority for local legislation. Additionally, the formatting and pagination of the posted documents varies from the formatting and pagination of the official copy. The official printed copy of a Code of Ordinances should be consulted prior to any action being taken.
For further information regarding the official version of any of this Code of Ordinances or other documents posted on this site, please contact the Municipality directly or contact American Legal Publishing toll-free at 800-445-5588.
Hosted by: American Legal Publishing
Back to Code Library
Previous Doc
Next Doc
0 items available
Detected legislative history
- Ordinances of Sheffield Lake, OH
- ORDINANCES OF THE CITY OF SHEFFIELD LAKE, OHIO
- ORDINANCE NO. 116-84
- ORDINANCES OF SHEFFIELD LAKE
- REPEALED)
- Repealed)
- adopted by any nationally recognized association
- ordance with approved standards
- Ord. 45-64
- Ordinances and/or any other documents that appear on this site may not reflect the most current legislation adopted by the Municipality
- Ordinances should be consulted prior to any action being taken
- Ordinances or other documents posted on this site, please contact the Municipality directly or contact American Legal Publishing toll-free at 800-445-5588
Imported automatically by MunicipalWiki. The original publisher remains the authoritative source pending legal normalization and verification.
No comments to display
No comments to display